Ashok Leyland
50 kVA Diesel Genset
50kVA prime
Prime power
CPCB norms compliant
Engine model
AL4DT G3, 76.4 HP, Turbocharged, mechanical A1 governing
Alternator
Brushless, Single Bearing, IP23, Class H Insulated, +/-0.5% voltage regulation, 0.8PF Lag, 50Hz
Cylinders
4 - 104x118mm bore x stroke, 4009cc, 17.9:1 CR
Cooling
Water-cooled (radiator)
Fuel tank capacity
100 L
Runtime @ 75% load
—
Dimensions (L×W×H)
2800 × 1200 × 1375 mm
Dry weight
1,296 kg
Enclosure
Weatherproof acoustic canopy (brochure dimensions are inclusive of canopy)
Emission norm
CPCB norms
Control panel
Optional AMF control panel (AL 4522 or DSE 6020 controller)
Warranty
2 years (entire package)
Specifications per Ashok Leyland LEYPOWER's official "LP10-160 kVA" Diesel Generating Set Specification brochure. Verified via a 300dpi table re-render and bore x stroke x cylinder-count vs. stated displacement cross-check (2.088L/4.009L/5.7L engine families all matched). States Prime ratings only -- no separate Standby column. This rating shares one physical canopy/engine shell with a sibling rating as twin catalog SKUs rather than a Prime/Standby duty pair for a single product; each is modeled as its own row carrying only its own stated output figures. Brochure only states general CPCB-norms compliance, not a specific tier such as CPCB IV+ -- confirm current status with an authorized dealer before purchase.