GensetPedia
Kirloskar / KOEL 82.5 kVA diesel genset
Kirloskar / KOEL

82.5 kVA Diesel Genset

82.5kVA prime
Prime power
75dB(A)
Noise @ 1m
CPCB IV+ compliant
Engine model
Kirloskar 4R1190ETA 4G1, 77.2 kW (105 HP) Prime rated output at 1500 RPM, Turbocharged Aftercooled
Alternator
Brushless, Class H insulation, 91.1% efficiency @100% load 0.8pf, <20% max voltage dip at full load 0.8pf lag, <2 sec to build rated voltage, 415V (3P only), 50Hz
Cylinders
4, In-line - 110x125mm bore x stroke, 4.76L displacement, CRDi fuel system, G3 governing class (ISO 8528 Part V), 500hr lube oil change interval, 10L lube oil sump capacity, DOC+SCR exhaust aftertreatment with DEF/AdBlue dosing (25L tank, ISO 22241), 12V DC electric start
Cooling
Liquid cooled (radiator), 15.1L coolant capacity
Fuel tank capacity
200 L
Runtime @ 75% load
Dimensions (L×W×H)
3200 × 1350 × 1595 mm
Dry weight
1,800 kg
Enclosure
Emission norm
CPCB IV+
Control panel
KG640C microprocessor-based genset controller: graphical LCD display, phase voltages/currents, frequency, kVA/kW/kWh/kVAr, power factor, lube oil pressure, engine temperature, RPM, run hours, number of starts, fuel level, auto/manual stop, battery charge condition, AMF feature; diagnostics for battery charging failure, over/under speed, over current, over/under voltage, over kW, phase sequence/missing, mains under voltage, low fuel level, low lube oil pressure, high engine temperature, low/high battery voltage, over-crank protection, routine maintenance indicator, genset test facility, mains frequency; optional Modbus communication
Warranty
Download official spec sheet (PDF) ↓

Specifications per Kirloskar Oil Engines Ltd (Kirloskar Powergen)'s official "82.5-160 kVA CPCB IV+ Compliant" SL Series technical specification catalogue (print code 20240610/REV01/A4). Sourced from the open web (kirloskaroilengines.com) as part of a targeted search for the site's remaining zero-model brands. Verified via bore x stroke x cylinder-count vs. stated displacement cross-check (110x125mm x 4-cyl = 4.752L, matches stated 4.76L within rounding). Rated Prime only -- no Standby figure given. This range is the first Kirloskar range processed to add DEF/AdBlue dosing (25L tank, ISO 22241) and DOC+SCR (not just DOC+EGR) exhaust aftertreatment, consistent with SCR typically appearing at this power class across the site's other brands too. Noise (75 dBA) is the document's own stated design ceiling, not a certified per-unit test result. Two weight figures given (Dry, Wet w/o fuel) -- uses Dry per site convention. No fuel-consumption LPH figure stated anywhere -- left null. No warranty or price figure stated.

Compare with similar models