GensetPedia
Mahindra Powerol

625 kVA Diesel Genset

625kVA prime
Prime power
97L/hr
Fuel @ 75% load
75dB(A)
Noise @ 1m
CPCB II compliant
Engine model
Perkins 2806D-E18TAG 1A, 540 kW gross, TCA (Turbocharged Charge Air-cooled)
Alternator
CG/LS/Stamford/Equivalent, IP23, +/-1% voltage regulation, Class H insulation, max 25% unbalanced load across phases
Cylinders
6 - 145x183mm bore x stroke, 18100cc, G2 governing (ISO 8528), 24V DC electric start
Cooling
Water-cooled (radiator)
Fuel tank capacity
800 L
Runtime @ 75% load
~8.2 hrs
Dimensions (L×W×H)
5850 × 2000 × 2300 mm
Dry weight
7,500 kg
Enclosure
Acoustic canopy (CFD/CAE/NVH-optimized design, rated -10C to 55C ambient without external aid, draw-out fuel tank, fire-retardant acoustic/insulation material)
Emission norm
CPCB II
Control panel
Powerol AMF-ready controller with RS485 Modbus, 500-event log, remote start/stop, 7 configurable inputs and 4 DC outputs, sleep mode, engine run-time scheduler; optional Smart DG cloud monitoring
Warranty
Download official spec sheet (PDF) ↓

Specifications per Mahindra Powerol's official "400, 500 & 625 kVA Gensets" leaflet (print code JAN 21), Perkins-powered (2206D-E13TAG3 / 2506D-E15TAG2 / 2806D-E18TAG 1A). Verified via bore x stroke x cylinder-count vs. stated displacement cross-check (12.5L/15.2L/18.1L engine families all matched). No explicit Prime/Standby duty label stated -- treated as Prime per this site's established convention, same as the 250/320 kVA leaflet from the same series. This leaflet explicitly states "CPCB II approved" (visible badge on the product photo), a more specific claim than several other Mahindra leaflets processed. noise_db (75) is the brochure's stated design-compliance ceiling ("conform to the latest CPCB norms of <75 dBA"), not a certified per-unit test result. Fuel consumption assumes 0.85 specific gravity diesel per the brochure's own footnote.