Greaves Cotton

160 kVA Diesel Genset

160kVA prime
Prime power
26.2L/hr
Fuel @ 75% load
CPCB IV+ compliant
Engine model
GPWII-PIV-160M (engine model 6G11TAG32), 144.5 kWm gross engine power at 1500 RPM, TCAC
Alternator
LS (Leroy-Somer), 415V (3P only), 50Hz, 222.4A, 4P, rotating field, automatic voltage regulator, +/-1% voltage regulation, Class H insulation, 1 sealed bearing, flex disc coupling, 25% unbalanced load capability
Cylinders
6, in-line - 108x133mm bore x stroke, 7.31L displacement, 16.8:1 compression ratio, Elec/G3 governor, Isochronous frequency regulation, Dry air cleaner, DOC+SCR+ASC aftertreatment, DEF system (ISO 22241, DIN 70070): 40L tank, 1.7/1.3 LPH @100%/75% load
Cooling
Water-cooled (radiator), 35L coolant capacity (Eng+Rad), max ambient capability 50 deg C
Fuel tank capacity
260 L
Runtime @ 75% load
~9.9 hrs
Dimensions (L×W×H)
4020 × 1500 × 2290 mm
Dry weight
2,210 kg
Enclosure
Acoustic canopy
Emission norm
CPCB IV+
Control panel
DSE 6120 MKIII genset controller
Warranty
Download official spec sheet (PDF) ↓

Specifications per Greaves Power's official "CPCB IV+ Genset Technical Specifications" table (Excel export titled CPCB IV+ Genset Technical Specifications_20.07.2023.xlsx -- dated right at the July 2023 CPCB IV+ mandate rollout), covering the brand's current CPCB IV+ line from 5 to 500 kVA in both mechanically-governed ("Mech") and CRDI (common-rail, electronically-governed) variants. At 100/125/160/180/200 kVA both variants are offered as genuinely different physical products (different engine sub-model, governor architecture) sharing the same kVA/kWe headline number -- modeled as separate rows disambiguated -mech/-crdi; every other rating in this table is offered in only one variant. Cross-checked via bore x stroke x cylinder-count vs. stated displacement for all six distinct engine families (0.51L/0.612L/3.66L/4.87L/7.31L/10.04L/16.8L) -- all matched exactly or within rounding. Ratings from 75 kVA up require DEF/AdBlue (ISO 22241, DIN 70070) for SCR aftertreatment; below that, DOC or DOC+POC only, no DEF system. The source states two enclosure dimension sets per model ("As per TA" [type-approval/testing configuration] and "Overall") -- this row uses the larger "Overall" figures. No noise dB(A), warranty, or price data is stated anywhere in this document -- left null rather than assumed. The 57 kVA rating's stated kWe (50) doesn't follow the ~0.8 power-factor ratio seen on every other row in this table -- recorded as stated, not corrected. 400 kVA and 500 kVA share the identical 12V14TAG31 engine and kWm/HP figures despite different kVA output -- a retuned/differently loaded configuration of the same block, recorded as stated, not treated as a data-entry error.