Kirloskar / KOEL
200 kVA Diesel Genset
Kirloskar 6SL90ETA 4G1, 183.8 kW (250 HP) Prime rated output at 1500 RPM, Turbocharged Aftercooled
- Prime
- 200kVA
- Noise @ 1 m
- 75dB(A)
- Weight
- 3,850kg
- Fuel tank
- 460L

Specifications
Kirloskar / KOEL 200 kVA specifications
Engine and alternator
- Engine model
- Kirloskar 6SL90ETA 4G1, 183.8 kW (250 HP) Prime rated output at 1500 RPM, Turbocharged Aftercooled
- Cylinders
- 6, In-line - 118x135mm bore x stroke, 8.86L displacement, CRDi fuel system, G3 governing class (ISO 8528 Part V), 500hr lube oil change interval, 27L lube oil sump capacity, DOC+SCR exhaust aftertreatment with DEF/AdBlue dosing (45L tank, ISO 22241), integral set-mounted radiator tested for 50 deg C ambient, 24V DC electric start
- Alternator
- Brushless, Class H insulation, AREP winding (Auxiliary Regulation Excitation Principle), 92.8% efficiency @100% load 0.8pf, <20% max voltage dip at full load 0.8pf lag, <2 sec to build rated voltage, 415V (3P only), 50Hz
- Cooling
- Liquid cooled (radiator), 35.8L coolant capacity
- Control panel
- KG745 microprocessor-based genset controller: graphical LCD display, phase voltages/currents, frequency, kVA/kW/kWh/kVAr, power factor, lube oil pressure, engine temperature, RPM, run hours, number of starts, fuel level, auto/manual stop, battery charge condition, AMF feature; diagnostics for battery charging failure, over/under speed, over current, over/under voltage, over kW, phase sequence/missing, mains under voltage, earth fault trip, low fuel level, low lube oil pressure, high engine temperature, low/high battery voltage, over-crank protection, routine maintenance indicator, genset test facility, mains frequency; optional Modbus communication and synchronization
Fuel
- Fuel tank capacity
- 460 L
- Fuel use @ 75% load
- Not published by the maker
- Runtime @ 75% load
- Not published by the maker
Size and build
- Dimensions (L × W × H)
- 4550 × 1700 × 2005 mm
- Dry weight
- 3,850 kg
- Enclosure
- Not published by the maker
- Noise @ 1 m
- 75 dB(A)
Compliance and warranty
- Emission norm
- CPCB IV+
- Warranty
- Not published by the maker
- Indicative price
- Not published by the maker
Source & notes ›
Specifications per Kirloskar Oil Engines Ltd (Kirloskar Powergen)'s official "200-625 kVA HD Series CPCB IV+ Compliant" technical specification catalogue (print code 20240610/REV01/A4). Sourced from the open web (kirloskaroilengines.com) as part of a targeted search for the site's remaining zero-model brands. This is a GENUINELY DIFFERENT physical product from the site's existing "200-kva" Kirloskar row (SL Series, from a separate brochure) despite an identical 183.8kW rated output -- the HD variant uses a bigger 6SL90ETA engine (118x135mm, 8.86L, 24V electrical) vs. the SL variant's 6K1080ETA (105x125mm, 6.48L, 12V electrical) -- a heavier-duty engine block providing extra durability margin at the same nameplate kVA/kW, not a data-entry duplicate; disambiguated with a -hd slug suffix. Verified via bore x stroke x cylinder-count vs. stated displacement cross-check (118x135mm x 6-cyl = 8.858L, matches stated 8.86L). This document's own "Genset Model" column literally shows "KG4-200WS1" for this HD row -- identical to the SL Series' 200 kVA model code, unlike the 320/500/625 HD rows in the same table which all explicitly append "(HD)" -- likely a copy-paste omission in the source, not evidence the two are the same physical product (every other spec differs). Rated Prime only -- no Standby figure given. DOC+SCR aftertreatment with DEF/AdBlue dosing (45L tank, ISO 22241). Noise (75 dBA) is the document's own stated design ceiling. Two weight figures given (Dry, Wet w/o fuel) -- uses Dry. No fuel-consumption LPH or warranty/price figure stated.